Home
>
Products
>
Laboratory benchtop water quality analyzer
>
INTELLIGENT LABORATOR multi-parameter water quality tester

ERUN-ST7

INTELLIGENT LABORATOR multi-parameter water quality tester
Widely applicable to the determination of drinking water, surface water and sewage.
INTELLIGENT LABORATOR multi-parameter water quality tester
INTELLIGENT LABORATOR multi-parameter water quality tester
INTELLIGENT LABORATOR multi-parameter water quality tester
INTELLIGENT LABORATOR multi-parameter water quality tester
INTELLIGENT LABORATOR multi-parameter water quality tester
INTELLIGENT LABORATOR multi-parameter water quality tester
Introduction

Brand: Erun

INTELLIGENT LABORATOR multi-parameter water quality tester

number: ERUN-ST7

Parameters:  ammonia nitrogen, PH, hardness.

It can be used for intelligent laboratory water quality monitoring, to meet the water supply system water quality indicators testing, in line with the standard.

Parameters

Smart Lab Water Quality Tester can test indicators:

AMMONIA (AS N),TOTAL CHLORINE, FREE CHLORINE,  PERMANGANATE INDEX, IRON, MANGANESE, CHROMIUM (VI), CHLORIDE, NITRATE-N  (AS N), NITRITE-N (AS N), FLUORIDE, SULFATE, ALUMINUM, TOTAL  HARDNESS, TOTAL ALKALINITY, COLORITY, TURBIDITY, PH, WATER TEMPERATURE,  DISSOLVED TOTAL SOLIDS, DISSOLVED OXYGEN, ARSENIC, CADMIUM, COPPER, ZINC,  LEAD

numberparameter

measurement range

uniterror
1

COD

 (chromium method low range)

5-200 or 5-150mg/L5%

COD

(chromium method high range)

200-2000 or 150-2000mg/L5%
2Ammonia nitrogen(low range)0.02-5.00mg/L3%(F.S)
Ammonia nitrogen(high range)5.00-25.00mg/L3%(F.S)
3Total phosphorus (low range0.02-2.00mg/L5%(F.S)
Total phosphorushigh range2.00-10.00mg/L5%(F.S)
4Total nitrogen(low range0.10-10mg/L5%(F.S)
Total nitrogenhigh range10-100mg/L5%(F.S)
5CODMn (permanganate index )0.00-10.00mg/L0.2or5%
6 Residual chlorine (low range0.02-2.00mg/L0.1or5%
Residual chlorine (high range)2.00-10.00mg/L5%
7Total chlorine(low range0.02-2.00mg/L0.1or5%
  Total chlorinehigh range2.00-10.00mg/L5%
8Chlorine dioxide (low range0.05-2.00mg/L0.2or5%
Chlorine dioxide high range2.00-20.00mg/L5%
9Sulfate5-200mg/L5%
10Nitrate (nitrogen)0.02-10.0mg/L0.1or5%
11Phosphate (low range0.01-10.0mg/L0.2or5%
Phosphate high range10.0-50.0mg/L5%
12Nitrite nitrogen (low range0.02-1.0mg/L0.05or5%
Nitrite nitrogenhigh range1.0-5.0mg/L5%
13Sulfide0.005-1.000mg/L5%(F.S)
14Fluoride0.05-2.0mg/L5%(F.S)
15Cyanide 0.01-0.50mg/L5%(F.S)
16Bromide0.10-5.00mg/L5%(F.S)
17Formaldehyde0.05-2.5mg/L5%(F.S)
18Volatil (low range)0.20-5.0mg/L5%(F.S)
Volatil (high range5.0-10.0mg/L5%(F.S)
19Hydrazine0.01-0.50mg/L5%(F.S)
20

Benzoamine compound

(low range)

0.03-1.0mg/L5%(F.S)

   Benzoamine compounds

(high range)

1.0-5.0mg/L5%(F.S)
21Silica0.01-5.00mg/L5%(F.S)
22Total alkalinity(low range0-100mg/L5%(F.S)
Total alkalinityhigh range100-1000mg/L5%(F.S)
23Total hardness(low range0.1-5.0mg/L5%(F.S)
Total hardnesshigh range5.0-200.0mg/L5%(F.S)
24Chloride ion (chloride)0.20-100.0mg/L5%(F.S)
25Copper (Cu)(low range
0.02-1.0mg/L5%(F.S)
Copper (Cu)high range1.0-10.0mg/L5%(F.S)
26Zinc (Zn) 0.2-5.0mg/L5%(F.S)
27Nickel (Ni) (low range0.02-0.50mg/L5%(F.S)
Nickel (Ni)(high range
0.50-1.00mg/L5%(F.S)
Nickel (Ni)0.02-10.00mg/L5%(F.S)
28Ferrum(Fe)(low range0.0-5.0mg/L5%(F.S)
Ferrum(Fe)high range5.0-10.0mg/L5%(F.S)
29Hexavalent chromium0.01-1.00mg/L5%(F.S)
30Cadmium(Cd)0.05-0.50mg/L5%(F.S)
31Manganese (Mn)  (low range)0.01-0.10mg/L5%(F.S)
Manganese (Mn)  (high range)0.10-1.0mg/L5%(F.S)
Manganese (Mn) 0.02-5.00mg/L5%(F.S)
32Total chromium0.02-1.0mg/L5%(F.S)
33Aluminium (Al)(low range
0.01-0.40mg/L5%(F.S)
Aluminium (Al)high range0.40-4.00mg/L5%(F.S)
34Silver0.01-1.00mg/L5%(F.S)
35Molybdenum0.05-1.00mg/L5%(F.S)
36Arsenic(low range
0.004-0.100mg/L5%(F.S)
 Arsenichigh range0.100-0.500mg/L5%(F.S)
37Beryllium (Be) 0.001-0.10mg/L5%(F.S)
38Boron (B) 0.10-2.00mg/L5%(F.S)
39Mercury (Hg)0.002-0.50mg/L5%(F.S)
40Lead0.01-0.50mg/L5%(F.S)
41Chrominance (low range5-50PCU3%(F.S)
  Chrominance (high range50-500PCU3%(F.S)
42Turbidity0-400NTU≤2%(F.S)
43Suspended solids5-1000mg/L≤2%(F.S)
44PH(Electrode method)0.00-14.00PH±0.1
PH(Colorimetry)5.00-8.00
PH0.1±0.1
45Dissolved oxygen  (Colorimetry)0.1-10.0mg/L0.1±5%

Dissolved oxygen 

(Electrode method)

0.-20.0
mg/L
±0.2
46Ozone0.01-2.5mg/L5%(F.S)
47Anionic surfaceactive agent0.01-1.0mg/L5%(F.S)
48Available chlorine0.0-100.0mg/L5%(F.S)
49Chlorite0.00-20.00mg/L5%(F.S)
50Stibonium0.05-10.0mg/L5%(F.S)
51Conductivity (Electrode method)0.00µs/cm-199.9ms/cmms/cm±0.1 (F.S)
52Carbamide0.00-4.00mg/L8%(F.S)
53Cyanuric acid 5-200mg/L5%(F.S)
54Silicate0.01-5.00mg/L5%(F.S)
55Temperature(0-99℃)±1
56Ammonium ion0.02-25.00mg/L3%(F.S)
57Ferrous(low range0.0-5.00mg/L5%(F.S)
Ferroushigh range
5.00-10.00mg/L5%(F.S)
58
TDS(Electrode method
0.00µs/cm-199.9ms/cm
g/L±0.5%

Features
  • It can detect the concentration, absorbance and transmittance of nearly 100 parameters in water quality, and can store, print, query and upload them to the computer.

  • In addition to the factory curve up to 250 curves, the user can add 3500 curves, can calibrate the curves, and store into the instrument.

  • Store 100,000 records (including parameter name, concentration, unit, test time, operator number, etc.).

  • The instrument measurement method can be a straight line method or a broken line method. The broken line method can measure some parameters with poor linear accuracy.

  • The instrument can take backup measures for the curve and data records determined by the user, and can be restored in case of accidental loss.

  • The system has bilingual function and can be switched between Chinese and English.

+86 18166600151