Desktop multi-parameter water quality analyzer

ERUN-ST6
Widely used in industrial sewage, aquaculture, drinking water, scientific research institutions and other water quality testing.
ERUN-ST6
ERUN-ST6
ERUN-ST6
ERUN-ST6
ERUN-ST6
ERUN-ST6
Introduction

Brand: Erun 

Name: Laboratory bench-top multi-parameter water quality analysis 

Model number:ERUN-ST6

Parameters: suspended solids, ammonia nitrogen, total hardness, residual chlorine, phosphate, nitrite, copper, iron, etc.

Erun environmental protection production of desktop ERUN-ST6 can according to the user demand for COD, ammonia nitrogen, total phosphorus, total nitrogen, copper, iron, nickel, hexavalent chromium, phosphate, nitrite, more than 70 kinds of parameters, the instrument has stable optical performance, easy operation, high measurement accuracy, using a single wavelength light through the sample, according to the bert-bier's law, by measuring the absorbance value and then calculate the concentration of the sample.

Parameters
  • Weight: 5kg

  • Overall dimensions: 400✖310158mm;

  • Maximum absorbance error: 0.005A ;

  • Absorbance range: -2.000 to 2.000;

  • Reproducibility: this result is presented at 3% ;

  • Reading mode: concentration, absorbance, light transmittance ;

  • Optical stability: The light absorption value of the instrument is less than 0.002A in 20min ;

  • Wavelength: 420nm, 440nm, 470nm, 520nm, 540nm, 560nm, 610nm, 630nm, 660nm, 680nm, 700nm, customize any wavelength in the above range;

  • Measurement parameters: COD, ammonia nitrogen, total phosphorus, total nitrogen, copper, iron, nickel, hexavalent chromium, phosphate, nitrite and other more than 70 kinds of parameters, the user can customize the parameters.

  • measuring range 

    numberparametermeasurement rangeuniterror
    1COD
    (chromium method low range)
    5-200mg/L5%
    COD
    (chromium method high range)
    200-1000mg/L5%
    COD
    (
    chromium method high range)
    1000-2000
    mg/L
    5%
    2Ammonia nitrogen(low range)0.02-5.00mg/L3%(F.S)
    Ammonia nitrogen(high range)5.00-25.00mg/L3%(F.S)
    3Total phosphorus (low range0.02-2.00mg/L5%(F.S)
    Total phosphorushigh range2.00-10.00mg/L5%(F.S)
    4Total nitrogen(low range0.10-15mg/L5%(F.S)
    Total nitrogenhigh range15-150mg/L5%(F.S)
    5CODMn (permanganate index )0.00-10.00mg/L0.2or5%
    6 Residual chlorine (low range0.02-2.00mg/L0.1or5%
    Residual chlorine (high range)2.00-10.00mg/L5%
    7Total chlorine(low range0.02-2.00mg/L0.1or5%
      Total chlorinehigh range2.00-10.00mg/L5%
    8Chlorine dioxide (low range0.05-2.00mg/L0.2or5%
    Chlorine dioxide high range2.00-20.00mg/L5%
    9Sulfate5-200mg/L5%
    10Nitrate (nitrogen)0.02-10.0mg/L0.1or5%
    11Phosphate (low range0.01-10.0mg/L0.2or5%
    Phosphate high range10.0-50.0mg/L5%
    12Nitrite nitrogen (low range0.02-1.0mg/L0.05or5%
    Nitrite nitrogenhigh range1.0-5.0mg/L5%
    13Sulfide0.005-1.000mg/L5%(F.S)
    14Fluoride0.05-2.0mg/L5%(F.S)
    15Cyanide 0.01-0.50mg/L5%(F.S)
    16Bromide0.10-5.00mg/L5%(F.S)
    17Formaldehyde0.05-2.5mg/L5%(F.S)
    18Volatil (low range)0.20-5.0mg/L5%(F.S)
    Volatil (high range5.0-10.0mg/L5%(F.S)
    19Hydrazine0.01-0.50mg/L5%(F.S)
    20Benzoamine compounds
    (low range)
    0.03-1.0mg/L5%(F.S)
       Benzoamine compounds
    (high range)
    1.0-5.0mg/L5%(F.S)
    21Silica0.01-5.00mg/L5%(F.S)
    22Total alkalinity(low range0-100mg/L5%(F.S)
    Total alkalinityhigh range100-1000mg/L5%(F.S)
    23Total hardness(low range0.1-5.0mg/L5%(F.S)
    Total hardnesshigh range5.0-200.0mg/L5%(F.S)
    24Chloride ion (chloride)0.20-100.0mg/L5%(F.S)
    25Copper (Cu)(low range
    0.02-1.0mg/L5%(F.S)
    Copper (Cu)high range1.0-10.0mg/L5%(F.S)
    26Zinc (Zn) 0.2-5.0mg/L5%(F.S)
    27Nickel (Ni) (low range0.02-0.50mg/L5%(F.S)
    Nickel (Ni)(high range
    0.50-1.00mg/L5%(F.S)
    Nickel (Ni)0.02-10.00mg/L5%(F.S)
    28Ferrum(Fe)(low range0.0-5.0mg/L5%(F.S)
    Ferrum(Fe)high range5.0-10.0mg/L5%(F.S)
    29Hexavalent chromium0.01-1.00mg/L5%(F.S)
    30Cadmium(Cd)0.05-0.50mg/L5%(F.S)
    31Manganese (Mn)  (low range)0.01-0.10mg/L5%(F.S)
    Manganese (Mn)  (high range)0.10-1.0mg/L5%(F.S)
    Manganese (Mn) 0.02-5.00mg/L5%(F.S)
    32Total chromium0.02-1.0mg/L5%(F.S)
    33Aluminium (Al)(low range
    0.01-0.40mg/L5%(F.S)
    Aluminium (Al)high range0.40-4.00mg/L5%(F.S)
    34Silver0.01-1.00mg/L5%(F.S)
    35Molybdenum0.05-1.00mg/L5%(F.S)
    36Arsenic(low range
    0.004-0.100mg/L5%(F.S)
     Arsenichigh range0.100-0.500mg/L5%(F.S)
    37Beryllium (Be) 0.001-0.10mg/L5%(F.S)
    38Boron (B) 0.10-2.00mg/L5%(F.S)
    39Mercury (Hg)0.002-0.50mg/L5%(F.S)
    40Lead0.01-0.50mg/L5%(F.S)
    41Chrominance (low range5-50PCU3%(F.S)
      Chrominance (high range50-500PCU3%(F.S)
    42Turbidity0-400NTU≤2%(F.S)
    43Suspended solids5-1000mg/L≤2%(F.S)
    44PH(Colorimetry)5.00-8.00
    PH0.1±0.1
    45Dissolved oxygen  (Colorimetry)0.1-10.0mg/L0.1±5%
    46Ozone0.01-2.5mg/L5%(F.S)
    47Anionic surfaceactive agent0.01-1.0mg/L5%(F.S)
    48Available chlorine0.0-100.0mg/L5%(F.S)
    49Chlorite0.00-20.00mg/L5%(F.S)
    50Stibonium0.05-10.0mg/L5%(F.S)
    51Iodide0.02-1.00
    mg/L5%(F.S)
    52Barium (Ba) 0.00-5.00mg/L5%(F.S)
Features
  • The measurement wavelength is optional.

  • When recording the query, you can do a single print or page printing.

  • The system has bilingual function and can be switched between Chinese and English.

  • C can store 300 curves, D is 3500; C can store 1000 records, D is 100000.

  • Optical system optimization and upgrade (D), measurement system, accuracy, stability.

  • The instrument is operated by 5-inch large screen color touch screen with friendly operation interface.

  • The instrument has a variety of security measures, can set the boot and system setting input password.

  • In addition to the factory curve, users can add the curve, the calibration curve, and store it into the instrument.

  • The instrument can take backup measures for the curve and data records determined by the user, and can be restored in case of accidental loss.

  • The instrument has its own calibration function, self-calibration during operation, which can effectively eliminate the drift error caused by long-term use.

  • The parameters containing COD (chromium method), total phosphorus, total nitrogen and total chromium are equipped with a digestion instrument.

  • With the one-click recovery function, the one-click recovery can be realized when the factory curve and user curve data records are lost due to accidents.

  • It can detect the concentration, absorbance and transmittance of nearly 100 parameters in water quality, and can store, print, query and upload them to the computer.

  • The light intensity can be adjusted, divided into 16 levels, arbitrary setting, can effectively solve the measurement range expansion problem caused by the strength of the signal.

  • The instrument measurement method can be a straight line method or a broken line method. The broken line method can measure some parameters with poor linear accuracy.

  • In order to query the curve query, in addition to the curve equation, you can also query the standard value of each standard substance and the corresponding absorbance and calibration time and calibration personnel number, fully reproduce the state of the calibration.