TOC Analyzer with Full International Certifications – Your Reliable Partner for Water Quality Testing
For pharmaceutical companies, power plants, and electronics manufacturers seeking a TOC analyzer with CE certification, ISO 9001, and RoHS compliance, the ERUN-SP3-J3 Total Organic Carbon Analyzer delivers lab-grade accuracy with a detection limit as low as 1 ppb (0.1 μg/L) – making it one of the most sensitive and export-ready TOC analyzers available today.
Water quality directly impacts product safety, regulatory compliance, and operational efficiency. Whether you are testing pharmaceutical water, water for injection, purified water, deionized water, power plant water, or drinking water, the ERUN-SP3-J3 TOC analyzer provides precise, repeatable measurements of total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC), and non-purgeable organic carbon (NPOC). With CE, ISO 9001, and RoHS certifications fully in place, this instrument is designed for seamless export to global markets.
The ERUN-SP3-J3 TOC analyzer is built specifically for low-level TOC detection in ultrapure and deionized water with TOC content of1 ppm (1000 μg/L) or less. Its core advantages lie in three areas: certification readiness, operational simplicity, and regulatory compliance.
For any TOC analyzer destined for international markets, certification is non-negotiable. The ERUN-SP3-J3 holds CE certification (essential for EU market entry), ISO 9001 quality management certification, and RoHS compliance (restriction of hazardous substances). These certifications are not just paperwork – they are your guarantee that the instrument meets stringent European safety, health, and environmental protection requirements. For buyers outside China, this means zero customs delays and immediate deployability in regulated environments.
Detection limit is the single most critical specification for TOC analyzers used in pharmaceutical and semiconductor applications. The ERUN-SP3-J3 achieves a minimum detectable limit of 1 ppb (0.1 μg/L) with a detection range of 0.1–1000.0 μg/L. Accuracy error is ≤±5% and repeatability error ≤3%. For context, the United States Pharmacopeia (USP) Chapter <643> requires TOC analyzers for pharmaceutical water to detect organic carbon at levels as low as 500 ppb – the ERUN-SP3-J3 outperforms this requirement by a factor of 500.
Traditional TOC analyzers often require costly reagents, acid additives, catalysts, and carrier gases – driving up operational expenses. The ERUN-SP3-J3 employs UV catalytic oxidation technology that eliminates these consumables entirely. This means:
No daily maintenance fees for reagents or gases
No hazardous chemical handling – safer for operators and the environment
Lower total cost of ownership over the instrument‘s lifespan
For pharmaceutical and biotech applications, data integrity is paramount. The ERUN-SP3-J3 features password-protected system access and meets the requirements of FDA 21 CFR Part 11 – ensuring that electronic records are trustworthy, traceable, and audit-ready. This is a critical requirement for any TOC analyzer used in GMP-compliant pharmaceutical manufacturing.
The ERUN-SP3-J3 completes a full TOC analysis cycle in ≤5 minutes, with detection time under 3 minutes. For high-throughput laboratories and production line quality control, this speed translates to higher sample throughput and faster decision-making.
Parameter | Specification |
|---|---|
TOC Detection Range | 0.1–1000.0 μg/L |
Minimum Detectable Limit | 1 ppb (0.1 μg/L) |
Conductivity Measurement Range | 0.055 μS/cm–6.000 μS/cm |
Accuracy Error | ≤±5% |
Repeatability Error | ≤3% |
Zero Drift | ±2%/D |
Range Drift | ±2%/D |
Analysis Cycle | ≤5 min |
Sample Temperature Range | 0–100℃ |
Operating Temperature | 0–40℃ |
Relative Humidity | ≤90% |
Power Requirements | 220VAC ±10% 50Hz or 12V battery |
Power Consumption | 60W |
Dimensions | 276×132×198 mm |
Weight | 5 kg |
Source: ERUN-SP3-J3 product specifications
The system features automatic micro-injection with precisely controlled sample volume. The entire testing process introduces no pollutants and poses no harm to human body or environment.
The 8-inch Windows touchscreen interface delivers a user-friendly experience that minimizes training time and reduces operator error.
The ERUN-SP3-J3 supports both online and offline testing modes. An optional external online monitoring device is available for continuous, real-time monitoring applications. For laboratories processing multiple samples, an optional autosampler enables unattended, continuous testing of many different samples.
With 32 GB standard memory and unlimited storage duration, the instrument retains years of historical data. Records can be queried by inspection date, and the U disk data copy function allows one-click export of all data from a selected date.
The built-in buzzer alarm activates when measurements exceed preset limits – protecting the instrument and preventing misuse.
The modular design enables quick assembly, maintenance, and repair – minimizing downtime and extending instrument service life.
The system supports multiple heavy-duty printers directly connected to the host computer for convenient, fast printing of results.
The ERUN-SP3-J3 TOC analyzer is designed to meet the most stringent regulatory requirements worldwide:
Chinese Pharmacopoeia (CP2010) – “Total Organic Carbon Inspection Method”
United States Pharmacopeia (USP) Chapter <643> – System Suitability requirements
FDA 21 CFR Part 11 – Electronic records and signatures
CE Certification – EU safety, health, and environmental protection standards
ISO 9001 – International quality management system
RoHS Compliance – Restriction of hazardous substances
This comprehensive compliance portfolio makes the ERUN-SP3-J3 suitable for pharmaceutical production, power generation, electronics manufacturing, pure water testing, and domestic water quality monitoring.
Q: What is the detection limit of the ERUN-SP3-J3 TOC analyzer?
A: The minimum detectable limit is 1 ppb (0.1 μg/L) with a detection range of 0.1–1000.0 μg/L.
Q: What certifications does this TOC analyzer hold?
A: The ERUN-SP3-J3 holds CE certification, ISO 9001, and RoHS compliance – making it fully export-ready for global markets.
Q: What type of water samples can this TOC analyzer test?
A: It can test pharmaceutical water, water for injection, purified water, drinking water, deionized water, power plant water, and their sources.
Q: Does the analyzer require reagents or carrier gas?
A: No. The UV catalytic oxidation method eliminates the need for acid reagents, catalysts, and carrier gas – reducing operating costs.
Q: Is the instrument compliant with FDA regulations?
A: Yes. The system is password-protected and meets FDA 21 CFR Part 11 requirements for electronic records and data integrity.
Q: How long does a single TOC analysis take?
A: The analysis cycle is ≤5 minutes, with detection time under 3 minutes.
Winrun Environmental Protection Technology Group Co., Ltd. brings over years of expertise in water quality analysis instrumentation, backed by a 4500㎡ standardized production facility and a commitment to quality that has earned CE, ISO 9001, and RoHS certifications. Every ERUN-SP3-J3 TOC analyzer is engineered for precision, built for reliability, and certified for global deployment. When water quality matters – and regulatory compliance is non-negotiable – Erun delivers the TOC analysis solution you can trust.
ERUN-SP3-J3 Total Organic Carbon Analyzer product pageFor more information or to request a quote, please visit the .