Brand:Erun
TITLE:Total Organic Carbon Analyzer
Model:ERUN-SP3-J3
Parameters: TOC
Total Organic Carbon Analyzer ERUN-SP3-J3 can determine the pharmaceutical water, water for injection, purified water, drinking water, deionized water, power plant water and its water source total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC), non-blowdown total organic carbon (NPOC) and other indicators; widely used in pharmaceutical production, power generation, electronic production, pure water testing and water testing and other areas of life. It is widely used in pharmaceutical production, power generation, electronic production, pure water testing and domestic water testing and other fields.
TOC detection range | 0.1~1000.0ug/L |
Conductivity Measurement Range | 0.055uS/cm~6.000uS/cm |
Testable items | TOC, conductivity, temperature |
TOC detection accuracy | 0.1ug/L |
accuracy error | ≤±5% |
repeatability error | ≤3% |
zero drift | ±2%/D |
range drift | ±2%/D |
analysis cycle | ≤5min |
Sample temperature | 0~100℃ |
minimum detectable limit | 1ppb |
control method | touchscreens |
environmental temperature | 0~40℃ |
relative humidity | ≤90% |
Power Requirements | 220VAC≤±10% 50Hz or 12V battery |
power | 60W |
gauge | 276*132*198mm |
weights | 5Kg |
1、Automatic micro-injection, sample injection volume can be controlled, the whole process of testing without pollutants, no harm to the human body and the environment; 2、Adopting UV catalytic oxidation method, there is no need to add acid reagent, catalyst and carrier gas, and there is no need for additional daily maintenance fee; 3、8 inch windows touch screen, humanized operation interface, easy to operate and maintain; 4、The system is password-protected and meets the requirements of FDA-21 CFR Part 11; 5、With beep alarm function when exceeding the set upper limit value to protect the instrument and prevent misuse; 6、Optional external online monitoring device to meet the needs of online monitoring; 7、An optional autosampler is available for unattended continuous testing of many different samples; 8、Meets the requirements of the CP2010 edition of the "Total Organic Carbon Inspection Method" and USP Chapter 32-643, System Suitability; 9、Designed for testing deionized water with a TOC content of 1 ppm or less, it can be switched between on-line and off-line testing; 10、Massive memory with 32GB capacity as standard and unlimited storage time; 11、Detection is fast, with a detection time of less than 3 minutes; 12、History records can be queried according to the date of inspection, and the history files and data are clear; 13、With U disk data copy function, you can copy all the data in one day according to the date, which is convenient for data export and backup; 14、Can support multiple ++ heavy printers directly connected to the host computer, easy to operate, fast printing; 15、Modular design, quick and easy assembly, maintenance and repair. |